Mamography

CLINICAL TRAILS (Mammography)
• Compare the diagnostic performance of digital mammography vs screen-film mammography, as measured by the area under the Receiver Operating Characteristic (ROC) curve, sensitivity, specificity, and positive and negative predictive values, in the detection of breast cancer in women.
• Compare the diagnostic accuracy of the digital mammogram obtained using each of the individual manufacturer’s digital units vs screen-film mammography through retrospective reader studies.
• Determine the effects of patient characteristics, including age, lesion type, pathologic diagnosis, menopausal and hormonal status, breast density, and family history, on diagnostic accuracy of digital mammography.
• Determine the effects of technical parameters, including display type, machine type, and detector spatial and contrast resolution, on diagnostic accuracy of digital mammography.
• Determine the effect of reduced false-positive mammograms that are expected with digital mammography on the health-related quality of life and personal anxiety of women undergoing this screening experience.
• Compare the diagnostic performance of digital mammography with the rate of cancer in a set of cases through a retrospective reader study.
• Compare the effect of softcopy vs printed film display on the diagnostic performance of digital mammography through a retrospective reader study.
• Compare the effect of breast density on the diagnostic accuracy of digital mammography vs screen-film mammography through a retrospective reader study.
• Compare the image quality and breast radiation dose in digital vs screen-film mammography in these participants.
• Determine the temporal variations in image quality, breast radiation dose, and other quality control parameters in the participating study centers.
OUTLINE: This is a randomized, multicenter study. Participants with postitive screening results are stratified according to age (under 50 vs 50-59 vs 60-70 vs over 70). Participants are randomized to one of two treatment arms.
• Arm I: Participants undergo a two-view screen-film mammogram followed by a two-view digital mammogram of each breast.
• Arm II: Participants undergo a two-view digital mammogram followed by a two-view screen-film mammogram of each breast.

Quality of life is assessed before the screening mammogram in the first 800 women enrolled. In an additional 1,200 participants (600 with positive screening results and 600 with negative screening results), quality of life is assessed shortly after the screening mammogram and at 1 year.

Participants are followed at 1 year with a repeat screen-film or digital mammogram.

PROJECTED ACCRUAL: A total of 49,500 participants (24,750 per arm) will be accrued for this study within 18 months.